no message
This commit is contained in:
+20
-15
@@ -278,7 +278,7 @@ class Ladestation extends IPSModule
|
|||||||
// zurückgesetzt.
|
// zurückgesetzt.
|
||||||
if (
|
if (
|
||||||
$stationType === 3 &&
|
$stationType === 3 &&
|
||||||
$this->GetBuffer("SmartMeFullDetectionVersion") !== "2"
|
$this->GetBuffer("SmartMeFullDetectionVersion") !== "3"
|
||||||
) {
|
) {
|
||||||
$this->SetValue("Car_is_full", false);
|
$this->SetValue("Car_is_full", false);
|
||||||
$this->SetValue("Pending_Counter", 0);
|
$this->SetValue("Pending_Counter", 0);
|
||||||
@@ -287,7 +287,7 @@ class Ladestation extends IPSModule
|
|||||||
(float)$this->ReadPropertyInteger("Max_Current_abs")
|
(float)$this->ReadPropertyInteger("Max_Current_abs")
|
||||||
);
|
);
|
||||||
$this->SetBuffer("SmartMeChargingEnabled", "0");
|
$this->SetBuffer("SmartMeChargingEnabled", "0");
|
||||||
$this->SetBuffer("SmartMeFullDetectionVersion", "2");
|
$this->SetBuffer("SmartMeFullDetectionVersion", "3");
|
||||||
}
|
}
|
||||||
|
|
||||||
$usesEaseeGateway = $this->UsesEaseeGateway($stationType);
|
$usesEaseeGateway = $this->UsesEaseeGateway($stationType);
|
||||||
@@ -1043,11 +1043,10 @@ class Ladestation extends IPSModule
|
|||||||
abs((float)$chargingPowerWatts) >= 100;
|
abs((float)$chargingPowerWatts) >= 100;
|
||||||
$carIsFull = $carDetected && $wasFull && !$carIsCharging;
|
$carIsFull = $carDetected && $wasFull && !$carIsCharging;
|
||||||
|
|
||||||
// Ein aus einer früheren Regelungsunterbrechung gelernter Wert unter
|
// Pico liefert die verfügbare Stations-/Gruppenobergrenze direkt über
|
||||||
// dem Mindestladestrom darf die Station nicht dauerhaft blockieren.
|
// die API. Ein zuvor über den Soll-/Istvergleich gelernter Fahrzeugwert
|
||||||
// Ein korrekt bestätigtes Ladeende wird dagegen bis zum Abstecken oder
|
// darf deshalb den möglichen Ladestrom nicht dauerhaft begrenzen.
|
||||||
// bis zur erneuten Leistungsaufnahme gehalten.
|
if (!$carIsFull) {
|
||||||
if (!$carIsFull && (float)$this->GetValue("Max_Current") < 6) {
|
|
||||||
$this->SetValue("Max_Current", $maxCurrent);
|
$this->SetValue("Max_Current", $maxCurrent);
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -1597,22 +1596,28 @@ class Ladestation extends IPSModule
|
|||||||
if ($counter >= $requiredCycles) {
|
if ($counter >= $requiredCycles) {
|
||||||
$this->SetValue("Pending_Counter", 0);
|
$this->SetValue("Pending_Counter", 0);
|
||||||
if ($requestedMismatch) {
|
if ($requestedMismatch) {
|
||||||
$this->Calc_Max_Current($this->GetValue("Is_1_ph"));
|
if ($stationType === 3) {
|
||||||
|
|
||||||
// Smart-Me liefert keinen eindeutigen Status "Auto
|
// Smart-Me liefert keinen eindeutigen Status "Auto
|
||||||
// voll". Erst wenn während einer echten Freigabe über
|
// voll". Der berechnete Fahrzeugwert dient hier nur
|
||||||
// 90 Sekunden praktisch kein Strom angenommen wird,
|
// zur Ladeende-Erkennung und wird nicht als neue
|
||||||
// bestätigt der gelernte Wert unter 6 A das Ladeende.
|
// dauerhafte Stationsobergrenze gespeichert.
|
||||||
|
$learnedMaxCurrent = 2.5 + (
|
||||||
|
$actualPower /
|
||||||
|
($this->GetValue("Is_1_ph") ? 230 : 1.71 * 400)
|
||||||
|
);
|
||||||
|
|
||||||
if (
|
if (
|
||||||
$stationType === 3 &&
|
|
||||||
$this->GetBuffer("SmartMeChargingEnabled") === "1" &&
|
$this->GetBuffer("SmartMeChargingEnabled") === "1" &&
|
||||||
(float)$this->GetValue("Max_Current") > 0 &&
|
$learnedMaxCurrent > 0 &&
|
||||||
(float)$this->GetValue("Max_Current") < 6
|
$learnedMaxCurrent < 6
|
||||||
) {
|
) {
|
||||||
$this->SetValue("Car_is_full", true);
|
$this->SetValue("Car_is_full", true);
|
||||||
$this->ResetTimer();
|
$this->ResetTimer();
|
||||||
$this->ResetNullTimer();
|
$this->ResetNullTimer();
|
||||||
}
|
}
|
||||||
|
} else {
|
||||||
|
$this->Calc_Max_Current($this->GetValue("Is_1_ph"));
|
||||||
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
} else {
|
} else {
|
||||||
|
|||||||
+20
-15
@@ -288,7 +288,7 @@ class Ladestation_v2 extends IPSModule
|
|||||||
// zurückgesetzt.
|
// zurückgesetzt.
|
||||||
if (
|
if (
|
||||||
$stationType === 3 &&
|
$stationType === 3 &&
|
||||||
$this->GetBuffer("SmartMeFullDetectionVersion") !== "2"
|
$this->GetBuffer("SmartMeFullDetectionVersion") !== "3"
|
||||||
) {
|
) {
|
||||||
$this->SetValue("Car_is_full", false);
|
$this->SetValue("Car_is_full", false);
|
||||||
$this->SetValue("Pending_Counter", 0);
|
$this->SetValue("Pending_Counter", 0);
|
||||||
@@ -297,7 +297,7 @@ class Ladestation_v2 extends IPSModule
|
|||||||
(float)$this->ReadPropertyInteger("Max_Current_abs")
|
(float)$this->ReadPropertyInteger("Max_Current_abs")
|
||||||
);
|
);
|
||||||
$this->SetBuffer("SmartMeChargingEnabled", "0");
|
$this->SetBuffer("SmartMeChargingEnabled", "0");
|
||||||
$this->SetBuffer("SmartMeFullDetectionVersion", "2");
|
$this->SetBuffer("SmartMeFullDetectionVersion", "3");
|
||||||
}
|
}
|
||||||
|
|
||||||
$usesEaseeGateway = $this->UsesEaseeGateway($stationType);
|
$usesEaseeGateway = $this->UsesEaseeGateway($stationType);
|
||||||
@@ -1063,11 +1063,10 @@ class Ladestation_v2 extends IPSModule
|
|||||||
abs((float)$chargingPowerWatts) >= 100;
|
abs((float)$chargingPowerWatts) >= 100;
|
||||||
$carIsFull = $carDetected && $wasFull && !$carIsCharging;
|
$carIsFull = $carDetected && $wasFull && !$carIsCharging;
|
||||||
|
|
||||||
// Ein aus einer früheren Regelungsunterbrechung gelernter Wert unter
|
// Pico liefert die verfügbare Stations-/Gruppenobergrenze direkt über
|
||||||
// dem Mindestladestrom darf die Station nicht dauerhaft blockieren.
|
// die API. Ein zuvor über den Soll-/Istvergleich gelernter Fahrzeugwert
|
||||||
// Ein korrekt bestätigtes Ladeende wird dagegen bis zum Abstecken oder
|
// darf deshalb den möglichen Ladestrom nicht dauerhaft begrenzen.
|
||||||
// bis zur erneuten Leistungsaufnahme gehalten.
|
if (!$carIsFull) {
|
||||||
if (!$carIsFull && (float)$this->GetValue("Max_Current") < 6) {
|
|
||||||
$this->SetValue("Max_Current", $maxCurrent);
|
$this->SetValue("Max_Current", $maxCurrent);
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -1610,22 +1609,28 @@ class Ladestation_v2 extends IPSModule
|
|||||||
if ($counter >= $requiredCycles) {
|
if ($counter >= $requiredCycles) {
|
||||||
$this->SetValue("Pending_Counter", 0);
|
$this->SetValue("Pending_Counter", 0);
|
||||||
if ($requestedMismatch) {
|
if ($requestedMismatch) {
|
||||||
$this->Calc_Max_Current($this->GetValue("Is_1_ph"));
|
if ($stationType === 3) {
|
||||||
|
|
||||||
// Smart-Me liefert keinen eindeutigen Status "Auto
|
// Smart-Me liefert keinen eindeutigen Status "Auto
|
||||||
// voll". Erst wenn während einer echten Freigabe über
|
// voll". Der berechnete Fahrzeugwert dient hier nur
|
||||||
// 90 Sekunden praktisch kein Strom angenommen wird,
|
// zur Ladeende-Erkennung und wird nicht als neue
|
||||||
// bestätigt der gelernte Wert unter 6 A das Ladeende.
|
// dauerhafte Stationsobergrenze gespeichert.
|
||||||
|
$learnedMaxCurrent = 2.5 + (
|
||||||
|
$actualPower /
|
||||||
|
($this->GetValue("Is_1_ph") ? 230 : 1.71 * 400)
|
||||||
|
);
|
||||||
|
|
||||||
if (
|
if (
|
||||||
$stationType === 3 &&
|
|
||||||
$this->GetBuffer("SmartMeChargingEnabled") === "1" &&
|
$this->GetBuffer("SmartMeChargingEnabled") === "1" &&
|
||||||
(float)$this->GetValue("Max_Current") > 0 &&
|
$learnedMaxCurrent > 0 &&
|
||||||
(float)$this->GetValue("Max_Current") < 6
|
$learnedMaxCurrent < 6
|
||||||
) {
|
) {
|
||||||
$this->SetValue("Car_is_full", true);
|
$this->SetValue("Car_is_full", true);
|
||||||
$this->ResetTimer();
|
$this->ResetTimer();
|
||||||
$this->ResetNullTimer();
|
$this->ResetNullTimer();
|
||||||
}
|
}
|
||||||
|
} else {
|
||||||
|
$this->Calc_Max_Current($this->GetValue("Is_1_ph"));
|
||||||
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
} else {
|
} else {
|
||||||
|
|||||||
Reference in New Issue